CSW1 & CSW3 Series covering 200A to 8000A, frame sizes 1000AF to 7500AF, in 3P/4P configurations
Icu up to 150kA @ 400V, with fault clearing in ≤30ms before damage occurs
Standard AC 400/690V (CSW1), extended up to AC 1140V (CSW3) for mining, rail & special installations
Guards against overload, short circuit, earth fault, undervoltage, overvoltage & current-voltage imbalance
3 grades (IC5.0 / IC7.0 / IC8.0) with self-diagnosis, fault memory, thermal memory & functional test
Measures current, voltage, power, power factor, kWh, harmonics & demand — all in one device
Modbus protocol for SCADA integration and "four-remote" function (remote monitoring, control, measurement & signalling)
Zone interlocking ensures only the faulty section trips — no upstream blackouts in hospitals, data centers & process plants
Fixed & drawer types on all frames, horizontal/vertical wiring, usable as isolation switch
Mechanical life up to 30,000 operations, zero arcing distance design
IEC/EN 60947-2 compliant, CCC & CQC certified
Selective protection with zone interlocking trips only the faulty section, keeping the rest of your plant running
30ms fault clearing protects transformers, cables, motors and downstream equipment from burnout
Fault memory and self-diagnosis pinpoint the problem instantly — no guesswork, faster restoration
Built-in metering (V, I, PF, kWh, harmonics) means no need for separate meters and analyzers at the incomer
Modbus/SCADA integration lets your team monitor and operate breakers from the control room — no panel visits
200A to 8000A in a single product range simplifies procurement, spares and panel standardization
Up to 30,000 mechanical operations and zero arcing distance design reduce replacement and servicing costs
Auto reclosing for solar/PV projects means the same breaker works in your next green energy investment
Reliable operation from -40°C to +70°C and high-altitude compliance — no derating surprises
IEC/EN 60947-2, CCC & CQC certifications ensure bankable quality for consultants and project approvals.
Main incomer and bus coupler protection; overload, undervoltage and short-circuit protection for generators
Transformer LV-side outgoing feeders, main distribution boards for continuous-process industries
Main LV switchboards, riser feeders in high-rise buildings, malls and office towers
Selective protection with zone interlocking ensures uninterrupted power to critical IT loads
Critical infrastructure where unnecessary tripping is not an option — precise selective protection keeps supply continuous
CSW3 series with AC 800–1140V rating for high-voltage industrial and mining networks
Auto reclosing function designed for photovoltaic applications
Direct overload, undervoltage and short-circuit protection; suitable for infrequent starting of large motors and DG sets
Doubles as a measurement node — current, voltage, power, frequency, energy, demand & harmonics at the grid point
Can be used as an isolation switch (with isolation function symbol) when supplied without an intelligent controller.